100 kVp条件下碘克沙醇(270 mg I/mL)应用于肾动脉CTA 检查的可行性研究
其他题名: Feasibilityofusing100kVptechniqueinrenalarteryCTangiographywithiodixanol(270mgI/mL)
作者: 雷平贵; 赵永为; 王霄英; 王鹤; 张保翠; 杨学东; 高福生
关键词: 肾动脉 ; CT血管成像 ; 对比剂 ; 迭代重建 ; 辐射量 ; 体型特异性剂量估计 ; Renal artery ; Computed tomography angiography ; Contrast medium ; Iterative reconstruction ; Radia-tion dose ; Size-specific dose estimate
刊名: 放射学实践
发表日期: 2014
期: 4, 页:361-364
收录类别: 中国科技核心期刊
文章类型: Journal Article
摘要: 目的:探讨100 kVp条件下、使用碘克沙醇(270 mg I/mL)行肾动脉CTA检查的可行性。方法:18例行肾动脉CTA检查的连续病例根据CT扫描管电压分为两组:100 kVp组(10例)和120 kVp组(6例),记录2组的容积CT剂量指数(CTDIvol),计算体型特异性剂量估计(SSDE)值。由2位有经验的影像诊断医师对图像进行主观评分,包括:整体图像质量、图像细节(血管锐利程度、MPR显示分支、VR显示分支、MIP显示分支)。图像客观评价包括:目标血管和背景的CT值(腹主动脉动脉、双侧肾动脉、竖脊肌),对比噪声比(CNR)及信噪比(SNR)。两组间辐射剂量及客观评价指标的比较采用两独立样本 t 检验,主观评价指标的比较采用 Mann-Whitney U 检验。结果:100 kVp 组 CTDIvol 为(11.19±3.85)mGy,120 kVp组为(17.37±2.63)mGy,两组间差异有统计学意义(P<0.05)。100 kVp 组 SSDE 为(15.48±4.41)mGy,120 kVp组为(25.00±2.49)mGy,两组间差异有统计学意义(P<0.05)。主观评价:两组图像质量整体评分的差异无统计学意义(Z=-1.60,P>0.05);两组图像血管锐利程度评分的差异有统计学意义(Z=-2.162,P<0.05);两组中重组图像在显示血管分支方面,MPR(Z=-0.972,P>0.05)、VR(Z=-1.696,P>0.05)和 MIP 图像(Z=-1.626,P>0.05)间的差异均无统计学意义。客观评价:100 kVp 组腹主动脉 CT 值为(291±32)HU,120 kVp 组为(224±20)HU,两者差异有统计学意义(P<0.05);100 kVp 组肾动脉 CT 值为(278±37)HU,120 kVp 组为(222±15)HU,两者差异有统计学意义(P<0.05);空气CT值及标准差在100 kVp组分别为(-992±2)和(9±2)HU,120 kVp组分别为(-995±2)和(7±2)HU,两组间2个指标的差异均无统计学意义(P>0.05);两组图像的 CNR 分别为22±4及21±3,差异无统计学意义(P>0.05);两组图像的SNR分别为30±7及30±6,差异无统计学意义(P>0.05)。结论:100 kVp条件下应用碘克沙醇(270 mg I/mL)行肾动脉CTA检查,图像质量能满足诊断要求且降低了辐射剂量。 Objective:To evaluate the feasibility of using 100kVp technique with iodixanol (270mg I/mL)in renal computed tomography angiography (CTA).Methods:Sixteen consecutive patients underwent renal artery CTA.They were divided into 100kVp group (10 patients)and 120kVp group (6 patients).The radiation dose and size-specific dose estima-tion (SSDE)of these two groups were recorded.The image quality was evaluated subjectively with 5 scale method by two experienced radiologists,including image quality as a whole,detail image quality (sharpness of blood vessels,blood vessel branches displayed on MPR,VR and MIP).The objective evaluation included attenuation of aimed blood vessels (abdominal aorta,bilateral renal arteries)and the attenuation of psoas major muscle at the same level as reference,and contrast-to-noise ratio (CNR),signal-to-noise ratio (SNR)were calculated.The radiation dose and objective evaluation parameters were stati-cally analyzed withttest,and the subjective evaluation parameters were analyzed with Mann-Whitney U test.Results:The CTDIvol in 100kVp group was (11.19±3.85)mGy,in 120kVp group was (17.37±2.63)mGy,with significant statistic difference (P<0.05).The SSDE of 100kVp group was (15.48±4.41)mGy,in 120kVp group was (25.00±2.49)mGy, with significant statistic difference (P<0.05).There was no significant difference in the image quality as a whole in subjec-tive evaluation between the 2 groups (Z= -1.60,P>0.05).Significant difference was existed in the sharpness of blood vessels between the 2 groups (Z= -2.162,P<0.05);whereas no statistic difference was showed in the vessel branches displayed on MPR,VR and MIP (Z= -0.972,P>0.05;Z= -1.696,P>0.05;Z= -1.626,P>0.05),respectively.For objective evaluation,the CT values of abdominal aorta and renal artery in 100kVp group and 120kVp group was [(291±32) vs (224±20)HU,P<0.05)]and [(278±37)vs (222±15)HU,P<0.05)]respectively,with significant statistic diffe-rences.The CT value and standard deviation in 100kVp group was (-992 ±2)and (9 ±2)HU respectively,in 120kVp group was (-995±2)and (7±2)HU respectively,with no statistic difference (P>0.05).The CNR and SNR in 100kVp group and 120kVp group were (22±4)vs (21±3),and (30±7)vs (30±6)respectively,with no statistic difference (P>0.05).Conclusion:Renal CTA with 100kVp and iodixanol (270mg I/mL)as contrast medium can provide satisfactory im-age quality as well as significant reduction of radiation exposure.
语种: 中文
原文出处: 查看原文
内容类型: 期刊论文
URI标识: http://ir.bjmu.edu.cn/handle/400002259/42652
Appears in Collections:北京大学第一临床医学院_医学影像科_期刊论文

Files in This Item:

There are no files associated with this item.


作者单位: 北京大学第一医院医学影像科, 北京,100034
Service
Recommend this item
Sava as my favorate item
Show this item's statistics
Export Endnote File
Google Scholar
Similar articles in Google Scholar
[雷平贵]'s Articles
[赵永为]'s Articles
[王霄英]'s Articles
CSDL cross search
Similar articles in CSDL Cross Search
[雷平贵]‘s Articles
[赵永为]‘s Articles
[王霄英]‘s Articles
Related Copyright Policies
Null
Social Bookmarking
Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit
所有评论 (0)
暂无评论
 
评注功能仅针对注册用户开放,请您登录
您对该条目有什么异议,请填写以下表单,管理员会尽快联系您。
内 容:
Email:  *
单位:
验证码:   刷新
您在IR的使用过程中有什么好的想法或者建议可以反馈给我们。
标 题:
 *
内 容:
Email:  *
验证码:   刷新

Items in IR are protected by copyright, with all rights reserved, unless otherwise indicated.

 

 

Valid XHTML 1.0!
Copyright © 2007-2017  北京大学医学部 - Feedback
Powered by CSpace