英文摘要

This study was to design a method to quantitatively evaluate three-dimensional (3D) reconstruction accuracy of spatial relationship of dental models based on a 7-axis contact 3D measuring system, and to evaluate the accuracy of a common regional registration method for edentulous jaw relation reconstruction. 3D surface data of edentulous dental casts with 10 positioning cylinders and wax occlusion rims of five patients were obtained using a dental scanner. The jaw relation was reconstructed using the common regional registration in the Geomagic software. Measurements were obtained for line length, vertical distance and horizontal distance between centric points from two sources with upper jaw model base plane as a reference plane. The statistical description of measurement data was done. (k) over bar +/- s of line length, vertical distance and horizontal distance between the center points of each data set were 0.107 +/- 0.354, 0.076 +/- 0.576 and 0.108 +/- 0.530 mm, respectively. Data was analyzed using the paired samples t-test and one-way analysis of variance. Paired t-test results of each patient and one-way analysis of variance for the five patients showed no significant differences (P>0.05). Using the Faro Edge system and standardized positioning cylinders, quantitative evaluation of the 3D reconstruction accuracy of edentulous jaw relation was workable. And results of common regional registration method met clinical requirements.

语种英语
WOS记录号WOS:000327312600149
引用统计
被引频次:4[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.bjmu.edu.cn/handle/400002259/50211
专题北京大学口腔医学院
作者单位1.Peking Univ, Res Ctr Engn & Technol Digital Dent, Sch Stomatol, Ctr Digital Dent,Minist Hlth, Beijing 100871, Peoples R China
2.Peking Univ, Natl Engn Lab Digital & Mat Technol Stomatol, Beijing 100871, Peoples R China
推荐引用方式
GB/T 7714
Sun, Yuchun,Yuan, Fusong,Li, Hong,et al. Evaluation of the accuracy of a common regional registration method for three-dimensional reconstruction of edentulous jaw relation by a 7-axis three-dimensional measuring system[J]. BIO-MEDICAL MATERIALS AND ENGINEERING,2014,24(1):1275-1287.
APA Sun, Yuchun,Yuan, Fusong,Li, Hong,Zhao, Yijiao,Lv, Peijun,&Wang, Yong.(2014).Evaluation of the accuracy of a common regional registration method for three-dimensional reconstruction of edentulous jaw relation by a 7-axis three-dimensional measuring system.BIO-MEDICAL MATERIALS AND ENGINEERING,24(1),1275-1287.
MLA Sun, Yuchun,et al."Evaluation of the accuracy of a common regional registration method for three-dimensional reconstruction of edentulous jaw relation by a 7-axis three-dimensional measuring system".BIO-MEDICAL MATERIALS AND ENGINEERING 24.1(2014):1275-1287.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Sun, Yuchun]的文章
[Yuan, Fusong]的文章
[Li, Hong]的文章
百度学术
百度学术中相似的文章
[Sun, Yuchun]的文章
[Yuan, Fusong]的文章
[Li, Hong]的文章
必应学术
必应学术中相似的文章
[Sun, Yuchun]的文章
[Yuan, Fusong]的文章
[Li, Hong]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。