英文摘要:

Purpose: The aim of this study was to assess the effect of various tube parameters on corneal endothelial cell density (ECD) after insertion of Ahmed valves.

Methods: Thirty-nine eyes of 33 patients with previous super-otemporal (ST) Ahmed valve implantation and 20 eyes of 13 participants with previous uncomplicated phacoemulsification and intraocular lens implantation but no history of glaucoma surgery were evaluated. Various tube parameters were measured with anterior segment optical coherence tomography. ST, central, and inferonasal (IN) ECD and pachymetry were measured. Endothelial cell loss and corneal thickness in the ST cornea was compared with those in the IN cornea.

Results: The mean age of the operated patients was 58 +/- 22 years, and the mean time since glaucoma surgery was 2.5 +/- 2.6 years. Thirty-two of the 39 study eyes were pseudophakic. The ECD was significantly lower in the ST endothelium than in the IN endothelium in eyes with glaucoma tube surgery (P < 0.001), although this relative reduction in ST ECD was not greater than that seen in pseudophakic control eyes (P = 0.16). In univariate analysis, tube angle relative to the cornea and distance from the tip of the tube to the cornea were significant risk factors for decreased ST endothelial cell loss when assessed relative to the IN ECD (P = 0.01 and P = 0.02, respectively). In multivariate analysis, only the distance of the tube tip to the cornea remained significantly associated with ST endothelial cell loss.

Conclusions: Although this was a retrospective study with inherent limitations, tubes that are closer to the cornea seem to lead to increased loss of adjacent endothelial cells.

语种: 英语
项目资助者: Research to Prevent Blindness, Inc ; That Man May See, Inc.
WOS记录号: WOS:000345924700011
Citation statistics:
内容类型: 期刊论文
URI标识: http://ir.bjmu.edu.cn/handle/400002259/51545
Appears in Collections:北京大学第二临床医学院_眼科_期刊论文

Files in This Item:

There are no files associated with this item.


作者单位: 1.Univ Calif San Francisco, Dept Ophthalmol, San Francisco, CA USA
2.Peking Univ, Peoples Hosp, Dept Ophthalmol, Beijing 100871, Peoples R China
3.Univ Calif San Francisco, Francis I Proctor Fdn, San Francisco, CA 94143 USA
4.Univ Maryland, Sch Med, Dept Ophthalmol & Visual Sci, Baltimore, MD 21201 USA

Recommended Citation:
Koo, Euna B.,Hou, Jing,Han, Ying,et al. Effect of Glaucoma Tube Shunt Parameters on Cornea Endothelial Cells in Patients With Ahmed Valve Implants[J]. CORNEA,2015,34(1):37-41.
Service
Recommend this item
Sava as my favorate item
Show this item's statistics
Export Endnote File
Google Scholar
Similar articles in Google Scholar
[Koo, Euna B.]'s Articles
[Hou, Jing]'s Articles
[Han, Ying]'s Articles
CSDL cross search
Similar articles in CSDL Cross Search
[Koo, Euna B.]‘s Articles
[Hou, Jing]‘s Articles
[Han, Ying]‘s Articles
Related Copyright Policies
Null
Social Bookmarking
Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit

Items in IR are protected by copyright, with all rights reserved, unless otherwise indicated.

 

 

Valid XHTML 1.0!
Copyright © 2007-2017  北京大学医学部 - Feedback
Powered by CSpace