北京大学医学部机构知识库
Advanced  
IR@PKUHSC  > 北京大学第三临床医学院  > 心血管内科  > 期刊论文
学科主题: 临床医学
题名:
Usefulness of lumen area parameters determined by intravascular ultrasound to predict functional significance of intermediate coronary artery stenosis
作者: Cui Ming1; Zhu Dan2; Guo Li-jun1,3,4; Song Li-ying2; Zhang Yong-zhen1,3,4; Zhang Fu-chun1,3,4; Niu Jie1,3,4; Wang Gui-song1,3,4; Han Jiang-li1,3,4; Gao Wei1,3,4
关键词: fractional flow reserve ; intravascular ultrasound ; intermediate coronary lesion ; minimal lumen area
刊名: CHINESE MEDICAL JOURNAL
发表日期: 2013-05-05
DOI: 10.3760/cma.j.issn.0366-6999.20123358
卷: 126, 期:9, 页:1606-1611
收录类别: SCI
文章类型: Article
WOS标题词: Science & Technology
类目[WOS]: Medicine, General & Internal
研究领域[WOS]: General & Internal Medicine
关键词[WOS]: FRACTIONAL FLOW RESERVE ; INTERVENTION ; SEVERITY ; ANGIOPLASTY ; ANGIOGRAPHY ; CRITERIA ; OUTCOMES ; DISEASE
英文摘要:

Background Coronary artery disease is the leading cause of death in China. Percutaneous coronary intervention is a recent milestone technology for treatment coronary artery disease. However, clinical decision making for patients with intermediate coronary stenosis is still controversial. We designed this study to assess the optimal intravascular ultrasound (IVUS) criteria for predicting functional significance of intermediate coronary lesions.

Methods We enrolled 141 patients with 165 intermediate coronary lesions located in vessels with a diameter >= 2.50 mm. IVUS of intermediate coronary lesions were performed before intervention. Pressure-derived fractional flow reserve (FFR) was measured at maximal hyperemia induced by adenosine infusion. An FFR <0.80 was considered as abnormal functional significance.

Results For the overall 165 lesions, the mean FFR value was 0.84 +/- 0.09. The diameter of the stenosis by visual estimation on angiogram was (59.63 +/- 11.29)%. Minimum lumen diameter (MLD), minimum lumen area (MLA) and plaque burden (PB) were (2.00 +/- 0.36) mm, (3.88 +/- 1.34) mm(2), (67.28 +/- 9.89)% respectively by IVUS measurements. An FFR <0.80 was seen in 43 lesions (30.5%). There was a moderate correlation between IVUS parameters and FFR, including MLD (r=0.372, P <0.001), MLA (r=0.442, P <0.001) and PB (r=-0.172, P <0.05). MLA was a predictor for FFR as a continuous variable independent of possible confounding variables (P <0.05), and MLA and PB, were predictors for FFR <0.80 as binary variables (P <0.05). The best cutoff value of MLA to predict FFR <0.80 was <3.15 mm(2), with a 73.6% diagnostic accuracy; sensitivity 71.4%, specificity 67.0%, AUC=0.709, and P <0.001. The cutoff value of the PB to predict FFR <0.80 was 65.45%; sensitivity 82.6%, specificity 41.2%, AUC=0.644, and P <0.01. If both MLA and PB were taken into account, the negative predictive value and the positive predictive value were 88.7% and 64.8% respectively.

Conclusions Anatomic measurements of intermediate coronary lesions obtained by IVUS showed a moderate correlation to FFR values. IVUS-derived MLA >= 3.15 mm(2) may be useful to exclude FFR <0.80, but poor specificity limits its applicability for physiological assessment of lesions <3.15 mm(2). MLA was one of many factors affecting coronary flow hemodynamics. Both MLA and PB should be taken into account when determining functional ischemia.

语种: 英语
所属项目编号: Z111107058811003 ; 81070260 ; 81200167 ; 81070260 ; 81200167 ; 7102099
项目资助者: Capital Characteristic Clinical Application Research from Beijing Science and Technology Committee ; National Natural Science Foundation of China ; Beijing Natural Science Foundation ; Young Core Fund from Peking University Third Hospital
WOS记录号: WOS:000319529100002
Citation statistics:
内容类型: 期刊论文
URI标识: http://ir.bjmu.edu.cn/handle/400002259/52034
Appears in Collections:北京大学第三临床医学院_心血管内科_期刊论文

Files in This Item:

There are no files associated with this item.


作者单位: 1.Peking Univ, Hosp 3, Dept Med, Beijing 100191, Peoples R China
2.Minist Educ, Key Lab Mol Cardiovasc Sci, Beijing 100191, Peoples R China
3.Peking Univ, Hosp 3, Dept Cardiol, Beijing 100191, Peoples R China
4.Minist Hlth, Key Lab Cardiovasc Mol Biol & Regulatory Peptides, Beijing 100191, Peoples R China

Recommended Citation:
Cui Ming,Zhu Dan,Guo Li-jun,et al. Usefulness of lumen area parameters determined by intravascular ultrasound to predict functional significance of intermediate coronary artery stenosis[J]. CHINESE MEDICAL JOURNAL,2013,126(9):1606-1611.
Service
Recommend this item
Sava as my favorate item
Show this item's statistics
Export Endnote File
Google Scholar
Similar articles in Google Scholar
[Cui Ming]'s Articles
[Zhu Dan]'s Articles
[Guo Li-jun]'s Articles
CSDL cross search
Similar articles in CSDL Cross Search
[Cui Ming]‘s Articles
[Zhu Dan]‘s Articles
[Guo Li-jun]‘s Articles
Related Copyright Policies
Null
Social Bookmarking
Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit
所有评论 (0)
暂无评论
 
评注功能仅针对注册用户开放,请您登录
您对该条目有什么异议,请填写以下表单,管理员会尽快联系您。
内 容:
Email:  *
单位:
验证码:   刷新
您在IR的使用过程中有什么好的想法或者建议可以反馈给我们。
标 题:
 *
内 容:
Email:  *
验证码:   刷新

Items in IR are protected by copyright, with all rights reserved, unless otherwise indicated.

 

 

Valid XHTML 1.0!
Copyright © 2007-2017  北京大学医学部 - Feedback
Powered by CSpace