Image quality of 256-multidetector computed tomography in patients with atrial fibrillation: an initial experience
作者: Chen, Chen; Zhuo, Liu; Nan, Hong
关键词: 256-MDCT ; Revolution CT ; Atrial fibrillation ; Cardiac CT ; Coronary angiography
刊名: EUROPEAN HEART JOURNAL SUPPLEMENTS
发表日期: 2015-09-01
DOI: 10.1093/eurheartj/suv052
卷: 17, 期:F, 页:F32-F36
收录类别: SCI
文章类型: Article
WOS标题词: Science & Technology
类目[WOS]: Cardiac & Cardiovascular Systems
研究领域[WOS]: Cardiovascular System & Cardiology
关键词[WOS]: 64-MDCT CORONARY-ANGIOGRAPHY ; 320-MDCT ; RHYTHM
英文摘要:

A series of studies on dual-source 64-multidetector computed tomography (MDCT) and 320-MDCT have demonstrated the feasibility of coronary computed tomography angiography for patients with atrial fibrillation (AF), although the examination is constrained by heart rhythm and rate. Theoretically, the newly marketed 256-MDCT (Revolution CT, GE Medical Systems, Waukesha, USA) is not limited by heart rate and rhythm, but it has not been confirmed by clinical studies. The objective of this study was to evaluate and compare the quality of 256-MDCT images obtained in patients with AF and in a control group of patients in sinus rhythm. Two reviewers were blinded to the patient groups and evaluated images of 15 coronary artery segments for each patient using 256-MDCT. The images were scored subjectively as 1 or 2, meaning of diagnostic quality, or 3, meaning poor quality. The effective doses of all patients were calculated. No statistical difference between the groups was noted in patient age (P = 0.318). The heart rates were 74.1 +/- 8.5 (SD) and 66.4 +/- 7.5 (SD) beats per minute in the AF group and control group, respectively, with significant difference (P = 0.004). Scores of 1 and 2 (diagnostic quality) were both assigned to 100% in sinus rhythm and AF. The overall mean image quality score for all three coronary arteries in AF was 1.12 +/- 0.32 (SD) and 1.10 +/- 0.28 (SD) in sinus rhythm, without significant difference (P = 0.278). The mean effective dose was 3.41 +/- 1.23 (SD) and 1.91 +/- 0.85 (SD) mSv in the AF and sinus rhythm groups, respectively. The analysis of our initial experience shows that the quality of all images obtained through 256-MDCT in AF patients meets the demands of diagnosis.

语种: 英语
WOS记录号: WOS:000366040900005
Citation statistics:
内容类型: 期刊论文
URI标识: http://ir.bjmu.edu.cn/handle/400002259/54422
Appears in Collections:北京大学第二临床医学院_放射科_期刊论文

Files in This Item:

There are no files associated with this item.


作者单位: Peking Univ, Peoples Hosp, Dept Radiol, Beijing 100044, Peoples R China

Recommended Citation:
Chen, Chen,Zhuo, Liu,Nan, Hong. Image quality of 256-multidetector computed tomography in patients with atrial fibrillation: an initial experience[J]. EUROPEAN HEART JOURNAL SUPPLEMENTS,2015,17(F):F32-F36.
Service
Recommend this item
Sava as my favorate item
Show this item's statistics
Export Endnote File
Google Scholar
Similar articles in Google Scholar
[Chen, Chen]'s Articles
[Zhuo, Liu]'s Articles
[Nan, Hong]'s Articles
CSDL cross search
Similar articles in CSDL Cross Search
[Chen, Chen]‘s Articles
[Zhuo, Liu]‘s Articles
[Nan, Hong]‘s Articles
Related Copyright Policies
Null
Social Bookmarking
Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit

Items in IR are protected by copyright, with all rights reserved, unless otherwise indicated.

 

 

Valid XHTML 1.0!
Copyright © 2007-2018  北京大学医学部 - Feedback
Powered by CSpace