北京大学医学部机构知识库
Advanced  
IR@PKUHSC  > 北京大学口腔医学院  > 期刊论文
学科主题: 口腔医学
题名:
Evaluation of the micro-shear bond strength of four adhesive systems to dentin with and without adhesive area limitation
作者: Chai, Yuan1,2,3; Lin, Hong1,2,3; Zheng, Gang1,2,3; Zhang, Xuehui1,2,3; Niu, Guangliang4; Du, Qiao4
关键词: Adhesive area limitation ; adhesive system ; dentin ; adhesive ; micro-shear bond strength
刊名: BIO-MEDICAL MATERIALS AND ENGINEERING
发表日期: 2015
DOI: 10.3233/BME-151290
卷: suppl.1, 页:S63-S72
收录类别: SCI
文章类型: Article
WOS标题词: Science & Technology
类目[WOS]: Engineering, Biomedical ; Materials Science, Biomaterials
研究领域[WOS]: Engineering ; Materials Science
关键词[WOS]: TENSILE ; ENAMEL
英文摘要:

The purpose of this study was to evaluate the bonding ability of four representative dentin-adhesive systems by applying the micro-shear bond strength (mu-SBS) test method and to evaluate the influence of adhesive area limitation on the bond strength. Two different adhesive application methods were used in the Ii-SBS test (with and without adhesives area limitation), and four representative adhesive systems were used in this study. Each dentin surface was treated with one of the four representative adhesive systems, and with twenty samples per group (n=20), each of the four groups underwent a Ii-SBS test. The results showed that the bond strength was significantly influenced by the adhesive application method (p<0.05), the adhesive type (p<0.05) and the interaction between the two factors (p<0.05). With regard to the four representative dentinadhesive systems, 3-E&R has a much better bond quality compared to the other adhesive systems. Furthermore, the microshear bond strength test method of restricting the area of both the adhesive and the resin is more reliable for evaluating the bonding property of adhesives to dentin, and it is also adequate for comparing the different adhesives systems.

语种: 英语
所属项目编号: 2012BAI22B03
项目资助者: National Science and Technology support program of China
WOS记录号: WOS:000361671800008
Citation statistics:
内容类型: 期刊论文
URI标识: http://ir.bjmu.edu.cn/handle/400002259/55176
Appears in Collections:北京大学口腔医学院_期刊论文

Files in This Item:

There are no files associated with this item.


作者单位: 1.Beijing Hosp Integrated Tradit & Western Med, Beijing, Peoples R China
2.Peking Univ, Sch & Hosp Stomatol, Dept Dent Mat, Beijing 100081, Peoples R China
3.Peking Univ, Sch & Hosp Stomatol, Dent Med Devices Testing Ctr, Beijing 100081, Peoples R China
4.Peking Univ, Sch & Hosp Stomatol, Natl Engn Lab Digital & Mat Technol, Beijing 100081, Peoples R China

Recommended Citation:
Chai, Yuan,Lin, Hong,Zheng, Gang,et al. Evaluation of the micro-shear bond strength of four adhesive systems to dentin with and without adhesive area limitation[J]. BIO-MEDICAL MATERIALS AND ENGINEERING,2015,suppl.1:S63-S72.
Service
Recommend this item
Sava as my favorate item
Show this item's statistics
Export Endnote File
Google Scholar
Similar articles in Google Scholar
[Chai, Yuan]'s Articles
[Lin, Hong]'s Articles
[Zheng, Gang]'s Articles
CSDL cross search
Similar articles in CSDL Cross Search
[Chai, Yuan]‘s Articles
[Lin, Hong]‘s Articles
[Zheng, Gang]‘s Articles
Related Copyright Policies
Null
Social Bookmarking
Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit
所有评论 (0)
暂无评论
 
评注功能仅针对注册用户开放,请您登录
您对该条目有什么异议,请填写以下表单,管理员会尽快联系您。
内 容:
Email:  *
单位:
验证码:   刷新
您在IR的使用过程中有什么好的想法或者建议可以反馈给我们。
标 题:
 *
内 容:
Email:  *
验证码:   刷新

Items in IR are protected by copyright, with all rights reserved, unless otherwise indicated.

 

 

Valid XHTML 1.0!
Copyright © 2007-2017  北京大学医学部 - Feedback
Powered by CSpace