IR@PKUHSC  > 北京大学第一临床医学院  > 放射治疗科
学科主题临床医学
CT angiography of pulmonary embolism using a 64 slice multi-detector scanner
Qin Nai-shan; Jiang Xue-xiang; Qiu Jian-xing; Zhu Ying; Wang Ji-chen
关键词Computed Tomographic Pulmonary Angiography Pulmonary Embolism Pulmonary Arteries Contrast Media
刊名CHINESE MEDICAL JOURNAL
2009-10-20
DOI10.3760/cma.j.issn.0366-6999.2009.20.020
122期:20页:2509-2515
收录类别SCI
文章类型Article
WOS标题词Science & Technology
类目[WOS]Medicine, General & Internal
研究领域[WOS]General & Internal Medicine
关键词[WOS]DEEP-VEIN THROMBOSIS ; PATIENT WEIGHT ; ELECTRON-BEAM ; SPIRAL CT ; DIAGNOSIS ; ENHANCEMENT ; ARTERIES
英文摘要

Background Multi-detector computed tomography (MDCT) has already been the first line investigation method for diagnosis of pulmonary embolism (PE). Reducing the amount of contrast medium used during CT scanning could decrease the incidental rate of adverse reactions. Our study amied to evaluate the image quality of pulmonary arteries using 64 slice multi-detector CT with small volumes of contrast media injection.

Methods Forty nonconsecutive patients without PE or other lung diseases were randomly assigned to two groups. Group A underwent CT scanning with 16x1.25 mm collimation and a 70 ml contrast injection, while group B had CT with 64x0.625 mm collimation and 20 ml of contrast injection. Two readers independently depicted the segmental and subsegmental pulmonary arteries. Reasons we could not analyze the pulmonary artery or that led to misdiagnosis of pulmonary embolism were evaluated, including the degree of contrast enhancement of the main pulmonary artery, and factors that caused misdiagnosis of PE (flow-related artifacts, partial volume artifact, beam-hardening artifacts and enhancement of pulmonary vein). The independent samples t-test, Mann-Whitney U test and Pearson chi-square test were applied.

Results There were no significant differences in image quality of segmental and subsegmental arteries between the two groups. No significant difference was found for factors that made pulmonary arteries non-analyzable or in the misdiagnosis of PE, except the degree of contrast enhancement.

Conclusion 64x0.625 mm collimation with 20 ml contrast injection could depict the pulmonary arteries well. Chin Med J 2009;122(20):2509-2515

语种英语
WOS记录号WOS:000271367000020
引用统计
被引频次:7[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.bjmu.edu.cn/handle/400002259/56112
专题北京大学第一临床医学院_放射治疗科
北京大学第一临床医学院_医学影像科
北京大学第二临床医学院_党委院长办公室
作者单位Peking Univ, Hosp 1, Dept Radiol, Beijing 100034, Peoples R China
推荐引用方式
GB/T 7714
Qin Nai-shan,Jiang Xue-xiang,Qiu Jian-xing,et al. CT angiography of pulmonary embolism using a 64 slice multi-detector scanner[J]. CHINESE MEDICAL JOURNAL,2009,122(20):2509-2515.
APA Qin Nai-shan,Jiang Xue-xiang,Qiu Jian-xing,Zhu Ying,&Wang Ji-chen.(2009).CT angiography of pulmonary embolism using a 64 slice multi-detector scanner.CHINESE MEDICAL JOURNAL,122(20),2509-2515.
MLA Qin Nai-shan,et al."CT angiography of pulmonary embolism using a 64 slice multi-detector scanner".CHINESE MEDICAL JOURNAL 122.20(2009):2509-2515.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Qin Nai-shan]的文章
[Jiang Xue-xiang]的文章
[Qiu Jian-xing]的文章
百度学术
百度学术中相似的文章
[Qin Nai-shan]的文章
[Jiang Xue-xiang]的文章
[Qiu Jian-xing]的文章
必应学术
必应学术中相似的文章
[Qin Nai-shan]的文章
[Jiang Xue-xiang]的文章
[Qiu Jian-xing]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。