Modified method of recording and reproducing natural head position with a multicamera system and a laser level
Liu, Xiao-jing1; Li, Qian-qian1; Pang, Yuan-jie2; Tian, Kai-yue1; xie, Zheng3; Li, Zi-li1
刊名AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS
2015-06-01
DOI10.1016/j.ajodo.2015.01.016
147期:6页:781-787
收录类别SCI
文章类型Article
WOS标题词Science & Technology
类目[WOS]Dentistry, Oral Surgery & Medicine
研究领域[WOS]Dentistry, Oral Surgery & Medicine
关键词[WOS]CEPHALOMETRIC ANALYSIS ; POSTURE ; INCLINOMETER ; MORPHOLOGY
英文摘要

Introduction: As computer-assisted surgical design becomes increasingly popular in maxillofacial surgery, recording patients′ natural head position (NHP) and reproducing it in the virtual environment are vital for preoperative design and postoperative evaluation. Our objective was to test the repeatability and accuracy of recording NHP using a multicamera system and a laser level. Methods: A laser level was used to project a horizontal reference line on a physical model, and a 3-dimensional image was obtained using a multicamera system. In surgical simulation software, the recorded NHP was reproduced in the virtual head position by registering the coordinate axes with the horizontal reference on both the frontal and lateral views. The repeatability and accuracy of the method were assessed using a gyroscopic procedure as the gold standard. Results: The interclass correlation coefficients for pitch and roll were 0.982 (0.966, 0.991) and 0.995 (0.992, 0.998), respectively, indicating a high degree of repeatability. Regarding accuracy, the lack of agreement in orientation between the new method and the gold standard was within the ranges for pitch (-0.69 degrees, 1.71 degrees) and for roll (-0.92 degrees, 1.20 degrees); these have no clinical significance. Conclusions: This method of recording and reproducing NHP with a multicamera system and a laser level is repeatable, accurate, and clinically feasible.

语种英语
WOS记录号WOS:000355378100024
项目编号2012AA041606 ; 2011-4025-03 ; PKUSSNCT-13A02
资助机构National High-Tech RD Program ; Capital Health Research and Development of Special ; Foundation of Peking University School and Hospital of Stomotology
引用统计
被引频次:3[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.bjmu.edu.cn/handle/400002259/56733
专题北京大学公共卫生学院
北京大学医学部管理机构_医学部
北京大学口腔医学院_外科
作者单位1.Peking Univ, Sch & Hosp Stomatol, Dept Oral & Maxillofacial Surg, Beijing 100871, Peoples R China
2.Johns Hopkins Bloomberg Sch Publ Hlth, Dept Epidemiol, Baltimore, MD USA
3.Peking Univ, Hlth Sci Ctr, Sch Publ Hlth, Beijing 100871, Peoples R China
推荐引用方式
GB/T 7714
Liu, Xiao-jing,Li, Qian-qian,Pang, Yuan-jie,et al. Modified method of recording and reproducing natural head position with a multicamera system and a laser level[J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS,2015,147(6):781-787.
APA Liu, Xiao-jing,Li, Qian-qian,Pang, Yuan-jie,Tian, Kai-yue,xie, Zheng,&Li, Zi-li.(2015).Modified method of recording and reproducing natural head position with a multicamera system and a laser level.AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS,147(6),781-787.
MLA Liu, Xiao-jing,et al."Modified method of recording and reproducing natural head position with a multicamera system and a laser level".AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS 147.6(2015):781-787.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Liu, Xiao-jing]的文章
[Li, Qian-qian]的文章
[Pang, Yuan-jie]的文章
百度学术
百度学术中相似的文章
[Liu, Xiao-jing]的文章
[Li, Qian-qian]的文章
[Pang, Yuan-jie]的文章
必应学术
必应学术中相似的文章
[Liu, Xiao-jing]的文章
[Li, Qian-qian]的文章
[Pang, Yuan-jie]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。