IR@PKUHSC  > 北京大学第一临床医学院  > 泌尿外科
学科主题临床医学
Measuring diagnostic accuracy of imaging parameters in pelvic lipomatosis
Zhang, Yudong; Wu, Shiliang; Xi, Zhijun; Wang, Xiaoying; Jiang, Xuexiang
关键词Computed Tomography (Ct) Cystitis Glandularis Hydronephrosis Magnetic Resonance Imaging (Mri) Pelvic Lipomatosis
刊名EUROPEAN JOURNAL OF RADIOLOGY
2012-11-01
DOI10.1016/j.ejrad.2012.05.031
81期:11页:3107-3114
收录类别SCI
文章类型Article
WOS标题词Science & Technology
类目[WOS]Radiology, Nuclear Medicine & Medical Imaging
研究领域[WOS]Radiology, Nuclear Medicine & Medical Imaging
关键词[WOS]CYSTITIS ; OBSTRUCTION
英文摘要

Objectives: To study whether the individual radiological findings can help predict diagnosis of pelvic lipomatosis (PL) or, specifically appreciate its progression.

Methods: Data from 32 clinically proven cases of PL and 25 controls were collected. Two reviewers were recruited for a blinded evaluation, image features were recorded in terms of: (1) bladder shape; (2) bladder-rectosigmoid morphological indexes including ratio of superior-inferior to anterior-posterior length of bladder (SI/AP), angle between anterior and posterior wall (AAP), relative length of posterior urethra (rLPU), angle between bladder and seminal vesicle (ABS) and rectosigmoid morphological index (RMI); (3) secondary complications. Results were evaluated by an unpaired t test and ROC analysis.

Results: The sensitivity and specificity were 40.6% and 100% for pear and banana-shaped bladder, 62.5% and 100% for SI/AP, 40.6% and 100% for AAP, 62.5% and 100% for ABS, 78.1% and 72% for rLPU, 59.4% and 96% for RMI, respectively. These radiological findings partially correlated with the severity of disease weighted by hydronephrosis and treatment grade. Image analysis demonstrated high prevalence of glandular cystitis (100%) and hydronephrosis (73.4%).

Conclusion: We conclude that PL is a progressive disease involving multiple pelvic organs with high prevalence of intractable cystitis and hydronephrosis. The imaging characteristics can help predict diagnosis and, specifically appreciate progression. (C) 2012 Elsevier Ireland Ltd. All rights reserved.

语种英语
WOS记录号WOS:000309554400029
引用统计
被引频次:5[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.bjmu.edu.cn/handle/400002259/56928
专题北京大学第一临床医学院_泌尿外科
作者单位Peking Univ, Hosp 1, Dept Urol, Dept Radiol, Beijing 100034, Peoples R China
推荐引用方式
GB/T 7714
Zhang, Yudong,Wu, Shiliang,Xi, Zhijun,et al. Measuring diagnostic accuracy of imaging parameters in pelvic lipomatosis[J]. EUROPEAN JOURNAL OF RADIOLOGY,2012,81(11):3107-3114.
APA Zhang, Yudong,Wu, Shiliang,Xi, Zhijun,Wang, Xiaoying,&Jiang, Xuexiang.(2012).Measuring diagnostic accuracy of imaging parameters in pelvic lipomatosis.EUROPEAN JOURNAL OF RADIOLOGY,81(11),3107-3114.
MLA Zhang, Yudong,et al."Measuring diagnostic accuracy of imaging parameters in pelvic lipomatosis".EUROPEAN JOURNAL OF RADIOLOGY 81.11(2012):3107-3114.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Zhang, Yudong]的文章
[Wu, Shiliang]的文章
[Xi, Zhijun]的文章
百度学术
百度学术中相似的文章
[Zhang, Yudong]的文章
[Wu, Shiliang]的文章
[Xi, Zhijun]的文章
必应学术
必应学术中相似的文章
[Zhang, Yudong]的文章
[Wu, Shiliang]的文章
[Xi, Zhijun]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。