IR@PKUHSC  > 北京大学口腔医学院
学科主题口腔医学
Evaluation of the Quantitative Accuracy of 3D Reconstruction of Edentulous Jaw Models with Jaw Relation Based on Reference Point System Alignment
Li, Weiwei1,2,3,4; Yuan, Fusong1,2,3,4; Lv, Peijun1,2,3,4; Wang, Yong1,2,3,4; Sun, Yuchun1,2,3,4
刊名PLOS ONE
2015-02-06
DOI10.1371/journal.pone.0117320
10期:2
收录类别SCI
文章类型Article
WOS标题词Science & Technology
类目[WOS]Multidisciplinary Sciences
资助者National Natural Science Foundation of China ; National High Technology Research and Development Program ; Scientific Research Staring Foundation for the Returned Overseas Chinese Scholars, Peking University School and Hospital of Stomatology ; National Natural Science Foundation of China ; National High Technology Research and Development Program ; Scientific Research Staring Foundation for the Returned Overseas Chinese Scholars, Peking University School and Hospital of Stomatology
研究领域[WOS]Science & Technology - Other Topics
关键词[WOS]VISUAL LOCATION RECOGNITION ; 3-D OBJECT RETRIEVAL
英文摘要

Objectives

To apply contact measurement and reference point system (RPS) alignment techniques to establish a method for 3D reconstruction of the edentulous jaw models with centric relation and to quantitatively evaluate its accuracy.

Methods

Upper and lower edentulous jaw models were clinically prepared, 10 pairs of resin cylinders with same size were adhered to axial surfaces of upper and lower models. The occlusal bases and the upper and lower jaw models were installed in the centric relation position. Faro Edge 1.8m was used to directly obtain center points of the base surface of the cylinders (contact method). Activity 880 dental scanner was used to obtain 3D data of the cylinders and the center points were fitted (fitting method). 3 pairs of center points were used to align the virtual model to centric relation. An observation coordinate system was interactively established. The straight-line distances in the X (horizontal left/right), Y (horizontal anterior/posterior), and Z (vertical) between the remaining 7 pairs of center points derived from contact method and fitting method were measured respectively and analyzed using a paired t-test.

Results

The differences of the straight-line distances of the remaining 7 pairs of center points between the two methods were X: 0.074 +/- 0.107 mm, Y: 0.168 +/- 0.176 mm, and Z: -0.003 +/- 0.155 mm. The results of paired t-test were X and Z: p >0.05, Y: p <0.05.

Conclusion

By using contact measurement and the reference point system alignment technique, highly accurate reconstruction of the vertical distance and centric relation of a digital edentulous jaw model can be achieved, which meets the design and manufacturing requirements of the complete dentures. The error of horizontal anterior/posterior jaw relation was relatively large.

语种英语
所属项目编号81271181 ; 2013AA040802
资助者National Natural Science Foundation of China ; National High Technology Research and Development Program ; Scientific Research Staring Foundation for the Returned Overseas Chinese Scholars, Peking University School and Hospital of Stomatology ; National Natural Science Foundation of China ; National High Technology Research and Development Program ; Scientific Research Staring Foundation for the Returned Overseas Chinese Scholars, Peking University School and Hospital of Stomatology
WOS记录号WOS:000349444900132
引用统计
被引频次:1[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.bjmu.edu.cn/handle/400002259/57024
专题北京大学口腔医学院
作者单位1.Natl Engn Lab Digital & Mat Technol Stomatol, Beijing, Peoples R China
2.Peking Univ, Sch & Hosp Stomatol, Ctr Digital Dent, Beijing 100871, Peoples R China
3.Peking Univ, Sch & Hosp Stomatol, Fac Prosthodont, Beijing 100871, Peoples R China
4.Minist Hlth, Res Ctr Engn & Technol Digital Dent, Beijing, Peoples R China
推荐引用方式
GB/T 7714
Li, Weiwei,Yuan, Fusong,Lv, Peijun,et al. Evaluation of the Quantitative Accuracy of 3D Reconstruction of Edentulous Jaw Models with Jaw Relation Based on Reference Point System Alignment[J]. PLOS ONE,2015,10(2).
APA Li, Weiwei,Yuan, Fusong,Lv, Peijun,Wang, Yong,&Sun, Yuchun.(2015).Evaluation of the Quantitative Accuracy of 3D Reconstruction of Edentulous Jaw Models with Jaw Relation Based on Reference Point System Alignment.PLOS ONE,10(2).
MLA Li, Weiwei,et al."Evaluation of the Quantitative Accuracy of 3D Reconstruction of Edentulous Jaw Models with Jaw Relation Based on Reference Point System Alignment".PLOS ONE 10.2(2015).
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Li, Weiwei]的文章
[Yuan, Fusong]的文章
[Lv, Peijun]的文章
百度学术
百度学术中相似的文章
[Li, Weiwei]的文章
[Yuan, Fusong]的文章
[Lv, Peijun]的文章
必应学术
必应学术中相似的文章
[Li, Weiwei]的文章
[Yuan, Fusong]的文章
[Lv, Peijun]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。