IR@PKUHSC  > 北京大学第三临床医学院  > 眼科
学科主题临床医学
Use of microperimetry to compare macular light sensitivity in eyes with open-angle and angle-closure glaucoma
Huang, Ping1; Shi, Yan1; Wang, Xin1; Zhang, Samuel Shao-Min2; Zhang, Chun1
关键词Microperimetry CACG POAG Macular function
刊名JAPANESE JOURNAL OF OPHTHALMOLOGY
2012-03-01
DOI10.1007/s10384-011-0111-6
56期:2页:138-144
收录类别SCI
文章类型Article
WOS标题词Science & Technology
类目[WOS]Ophthalmology
研究领域[WOS]Ophthalmology
关键词[WOS]OPTICAL COHERENCE TOMOGRAPHY ; VISUAL-FIELD ; FUNDUS PERIMETRY ; NORMAL INDIVIDUALS ; CAPILLARY DENSITY ; NERVE HEAD ; HYPERTENSION ; TOPOGRAPHY ; NEUROPATHY ; THRESHOLD
英文摘要

Use of microperimetry to compare macular light sensitivity in early and moderate primary open-angle glaucoma (POAG), chronic angle-closure glaucoma (CACG), and normal controls.

A cross-sectional, case-control, comparative study. A total of 126 eyes from 126 subjects, 53 normal eyes, 50 POAG eyes, and 23 CACG eyes were studied. A macular 10A degrees program was performed with MP-1 microperimetry. The mean sensitivities (MS) of the central 2A degrees, 6A degrees, and 10A degrees visual fields were compared among the POAG, CACG, and normal controls. The mean light sensitivities of the four quadrants in the central 6A degrees were also analyzed in each group.

The MS of the central 2A degrees, 6A degrees, 10A degrees, and total macular areas in the POAG patients were significantly reduced compared with those for the normal controls (all P < 0.05). The MS of the central 6A degrees, 10A degrees, and total areas, except those at the central 2A degrees, in the CACG patients were significantly reduced. In the central 6A degrees, more severe loss of MS was observed in the inferotemporal quadrant in the POAG group. In the CACG group, the reduction in the MS among the four quadrants was not significantly different (P = 0.623).

Different patterns of macular function damage were identified in both early and moderate stage POAG and in CACG patients.

语种英语
WOS记录号WOS:000301485300006
资助机构Pfizer Investment Co., Ltd., Beijing, China
引用统计
被引频次:6[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.bjmu.edu.cn/handle/400002259/58226
专题北京大学第三临床医学院_眼科
北京大学基础医学院
北京大学第三临床医学院_骨科
作者单位1.Peking Univ, Dept Ophthalmol, Hosp 3, Key Lab Vis Loss & Restorat,Minist Educ, Beijing 100191, Peoples R China
2.Penn State Univ, Coll Med, Penn State Hershey Eye Ctr, Dept Neural & Behav Sci, Hershey, PA 17033 USA
推荐引用方式
GB/T 7714
Huang, Ping,Shi, Yan,Wang, Xin,et al. Use of microperimetry to compare macular light sensitivity in eyes with open-angle and angle-closure glaucoma[J]. JAPANESE JOURNAL OF OPHTHALMOLOGY,2012,56(2):138-144.
APA Huang, Ping,Shi, Yan,Wang, Xin,Zhang, Samuel Shao-Min,&Zhang, Chun.(2012).Use of microperimetry to compare macular light sensitivity in eyes with open-angle and angle-closure glaucoma.JAPANESE JOURNAL OF OPHTHALMOLOGY,56(2),138-144.
MLA Huang, Ping,et al."Use of microperimetry to compare macular light sensitivity in eyes with open-angle and angle-closure glaucoma".JAPANESE JOURNAL OF OPHTHALMOLOGY 56.2(2012):138-144.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Use of microperimetr(246KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Huang, Ping]的文章
[Shi, Yan]的文章
[Wang, Xin]的文章
百度学术
百度学术中相似的文章
[Huang, Ping]的文章
[Shi, Yan]的文章
[Wang, Xin]的文章
必应学术
必应学术中相似的文章
[Huang, Ping]的文章
[Shi, Yan]的文章
[Wang, Xin]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Use of microperimetry to compare macular light sensitivity in eyes with open-angle and angle-closure glaucoma.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。