英文摘要:

Aim: To investigate the effects of differential sites for cold saline injection on transpulmonary thermodilution parameter values.

Methods: This was a prospective study. Twelve patients were recruited for the following examinations: control condition (injection site at proximal injection end of the Swan-Ganz catheter), proximal end condition (injection site at sheath of the Swan-Ganz catheter), and distal end condition (injection site at PA end of the Swan-Ganz catheter). Sixty measurements were performed for each condition. The cardiac index, global end diastolic volume index (GEDI), and extravascular lung water index for the three different injection sites were recorded from each patient. In addition, the mean transmission time (MTt), downslope time, and area under the curve obtained from PiCCO-VoLEF-Win software were compared among different groups.

Results: There were no differences in cardiac index and extravascular lung water index values among the three conditions (P>0.05). There were no differences in GEDI between the proximal end condition and control condition (P>0.05), while the GEDI was significantly lower for the distal end condition (493.33 +/- 254.65 mL/m(2)) than for the control condition (645.53 +/- 234.46 mL/m(2)) (P<0.05) and proximal end condition (717.96 +/- 321.63 mL/m(2)) (P<0.01). There were no differences in downslope time and area under the curve among the three conditions (P<0.05). There were no differences in MTt between the proximal end condition and control condition (P>0.05), while the MTt was significantly lower for distal end condition (40.22 +/- 16.37 seconds) than for the control condition (42.91 +/- 17.93 seconds) (P<0.05) and proximal end condition (47.16 +/- 16.64 seconds) (P<0.01).

Conclusion: The differential sites for cold saline injection impacted transpulmonary thermodilution parameter values.

语种: 英语
WOS记录号: WOS:000352542200001
Citation statistics:
内容类型: 期刊论文
URI标识: http://ir.bjmu.edu.cn/handle/400002259/58383
Appears in Collections:北京大学第二临床医学院_期刊论文

Files in This Item:

There are no files associated with this item.


作者单位: 1.Fifth Cent Hosp Tianjin, Dept Crit Care, Tianjin 332400, Peoples R China
2.Peking Univ, Peoples Hosp, Dept Crit Care, Beijing 100871, Peoples R China

Recommended Citation:
Yang, Wanjie,Feng, Qingguo,An, Youzhong,et al. The effects of differential injection sites of cold saline on transpulmonary thermodilution parameter values[J]. PATIENT PREFERENCE AND ADHERENCE,2015,9:551-554.
Service
Recommend this item
Sava as my favorate item
Show this item's statistics
Export Endnote File
Google Scholar
Similar articles in Google Scholar
[Yang, Wanjie]'s Articles
[Feng, Qingguo]'s Articles
[An, Youzhong]'s Articles
CSDL cross search
Similar articles in CSDL Cross Search
[Yang, Wanjie]‘s Articles
[Feng, Qingguo]‘s Articles
[An, Youzhong]‘s Articles
Related Copyright Policies
Null
Social Bookmarking
Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit
所有评论 (0)
暂无评论
 
评注功能仅针对注册用户开放,请您登录
您对该条目有什么异议,请填写以下表单,管理员会尽快联系您。
内 容:
Email:  *
单位:
验证码:   刷新
您在IR的使用过程中有什么好的想法或者建议可以反馈给我们。
标 题:
 *
内 容:
Email:  *
验证码:   刷新

Items in IR are protected by copyright, with all rights reserved, unless otherwise indicated.

 

 

Valid XHTML 1.0!
Copyright © 2007-2017  北京大学医学部 - Feedback
Powered by CSpace