英文摘要:

A biuret automated colorimetric assay for total protein in urine and cerebrospinal fluids was established. The procedures were as follows. Acidify all urine sample before analysis. Add precipitant Na2WO4 to urine samples. After 10 min, centrifuge, decant the supernatant fluid. drain the inverted tubes on absorbent tissue, dissolve the precipitation with 0.1 mol/L NaOH, and finally adapt the reconstituted urine to the Hitachi 7170 analyzer. A cell-free cerebrospinal fluid sample produced by centrifugation can be inserted in an auto-analyzer for protein measurement directly. The program: mix 35 mul sample (CSF or reconstituted urine) and standard with 0.2 mol/L NaOH; incurable at 37 degreesC for 5 min, and real A1. Add concentrated biuret reagent, and 10 min later measure absorbance A2 at 546 nm vs. reagent blank. Secondary wavelength was 700 nm. The test results were calculated against a one-point standard. This biuret colorimetric method was relatively simple, fast, and accurate for the determination of protein in urine and cerebrospinal fluid, with a wide linearity extending from 0.125 g/L up to 6 g/L, had a good correlation with Benzethonium chloride turbidimetry technique, and was a practical routine method. (C) 2001 Wiley-Liss, Inc.

语种: 英语
WOS记录号: WOS:000169717600001
Citation statistics:
内容类型: 期刊论文
URI标识: http://ir.bjmu.edu.cn/handle/400002259/59776
Appears in Collections:北京大学第一临床医学院_期刊论文

Files in This Item:

There are no files associated with this item.


作者单位: Beijing Univ, Div Med, Hosp 1, Dept Clin Chem, Beijing 100034, Peoples R China

Recommended Citation:
Xu, GB,Jiao, LL,Zhu, LH,et al. Application of an improved biuret method to the determination of total protein in urine and cerebrospinal fluid without concentration step by use of Hitachi 7170 auto-analyzer[J]. JOURNAL OF CLINICAL LABORATORY ANALYSIS,2001,15(4):161-164.
Service
Recommend this item
Sava as my favorate item
Show this item's statistics
Export Endnote File
Google Scholar
Similar articles in Google Scholar
[Xu, GB]'s Articles
[Jiao, LL]'s Articles
[Zhu, LH]'s Articles
CSDL cross search
Similar articles in CSDL Cross Search
[Xu, GB]‘s Articles
[Jiao, LL]‘s Articles
[Zhu, LH]‘s Articles
Related Copyright Policies
Null
Social Bookmarking
Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit

Items in IR are protected by copyright, with all rights reserved, unless otherwise indicated.

 

 

Valid XHTML 1.0!
Copyright © 2007-2017  北京大学医学部 - Feedback
Powered by CSpace