Evaluation of BD Vacutainer SST (TM) II Plus Tubes for Special Proteins Testing
作者: Li, Zhiyan; Yan, Cunling; Yan, Rong; Zheng, Xinzhi; Feng, Zhenru
关键词: BD SST (TM) II Plus Tubes ; serum separator tube ; stability ; barrier gel ; special proteins
刊名: JOURNAL OF CLINICAL LABORATORY ANALYSIS
发表日期: 2011
DOI: 10.1002/jcla.20458
卷: 25, 期:3, 页:203-206
收录类别: SCI
文章类型: Article
WOS标题词: Science & Technology
类目[WOS]: Medical Laboratory Technology
研究领域[WOS]: Medical Laboratory Technology
关键词[WOS]: BLOOD COLLECTION TUBES ; THERAPEUTIC DRUGS ; SERUM ; TIME ; ABSORPTION ; VOLUME ; GEL
英文摘要:

In the past few years, because of providing a closed system that allowed for collection, transport, processing, sampling, and storage of specimens, serum separator tubes gained widespread acceptance gradually in China. However, some limitations associated with gel tubes had been observed, for example, gel and analyte stability. In order to circumvent these problems, a new tube (BD Vacutainer(R) SST(TM) II Plus (BD SST(TM) II Plus)) containing a new gel was released by BD with respect to analyte and gel stability. We investigated the performance of BD SST(TM) II Plus tubes for special proteins testing using BD Vacutainer(R) Serum Glass Tubes (BD Serum Glass) as controls. Equivalence between these two types of tubes was demonstrated for all analytes at initial time, and data for all analytes except complement 3 (C3) and complement 4 (C4) indicated comparable stability over time in these two types of tubes. Concentration of C3 and C4 tended to increase with preservation time up to 72 hr in BD Serum Glass tubes. The stability of C3 and C4 was better in BD SST(TM) II Plus, which was demonstrated at timepoints up to 48 hr. We conclude that BD SST(TM) II Plus was suitable for collection and storage of samples for special proteins testing. J. Clin. Lab. Anal. 25:203-206, 2011. (C) 2011 Wiley-Liss, Inc.

语种: 英语
WOS记录号: WOS:000291110400010
Citation statistics:
内容类型: 期刊论文
URI标识: http://ir.bjmu.edu.cn/handle/400002259/60351
Appears in Collections:北京大学第一临床医学院_期刊论文

Files in This Item:

There are no files associated with this item.


作者单位: Peking Univ, Hosp 1, Dept Clin Lab, Beijing 100871, Peoples R China

Recommended Citation:
Li, Zhiyan,Yan, Cunling,Yan, Rong,et al. Evaluation of BD Vacutainer SST (TM) II Plus Tubes for Special Proteins Testing[J]. JOURNAL OF CLINICAL LABORATORY ANALYSIS,2011,25(3):203-206.
Service
Recommend this item
Sava as my favorate item
Show this item's statistics
Export Endnote File
Google Scholar
Similar articles in Google Scholar
[Li, Zhiyan]'s Articles
[Yan, Cunling]'s Articles
[Yan, Rong]'s Articles
CSDL cross search
Similar articles in CSDL Cross Search
[Li, Zhiyan]‘s Articles
[Yan, Cunling]‘s Articles
[Yan, Rong]‘s Articles
Related Copyright Policies
Null
Social Bookmarking
Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit

Items in IR are protected by copyright, with all rights reserved, unless otherwise indicated.

 

 

Valid XHTML 1.0!
Copyright © 2007-2017  北京大学医学部 - Feedback
Powered by CSpace