英文摘要:

Minimally-invasive cardiac output (CO) monitoring to follow changes in CO would be helpful in anaesthesia practice. Two Doppler systems marketed for this purpose include the CardioQ (Deltex Medical Group, Chichester, United Kingdom), which uses an oesophageal probe, and the USCOM (USCOM Ltd., Sydney, NSW, Australia), which uses a hand-held probe. The aim of the study was to assess the ability of these two methods to track CO during major surgery and to determine their relationship. Twenty patients, age 58 (26 to 81) years, (m/f) 15/5, requiring abdominal surgery were studied. The surgical procedures lasted between 128 and 408 minutes and a total of 285 data pairs (8 to 22 per case) were collected. Time plots showed good tracking ability across a wide range of CO in most patients. Correlation between the two devices was excellent in 14 patients (R-2 >0.85), good in another four (R-2 >0.64) and poor in two. Regression line data supported the hypothesis that CardioQ under-reads at low CO and over-reads at high CO in respect to the USCOM. However, the precision between the two CO readings was poor with wide limits of agreement and a percentage error of +/- 37%. These findings indicate that these devices individually track changes in CO in many patients but cannot be relied upon to provide the same values.

语种: 英语
所属项目编号: 2041689
项目资助者: Chinese University of Hong Kong
WOS记录号: WOS:000341959500014
Citation statistics:
内容类型: 期刊论文
URI标识: http://ir.bjmu.edu.cn/handle/400002259/60769
Appears in Collections:北京大学第一临床医学院_期刊论文

Files in This Item:

There are no files associated with this item.


作者单位: Peking Univ, Hosp 1, Dept Anaesthesia & Surg Intens Care, Beijing 100871, Peoples R China

Recommended Citation:
Huang, L.,Critchley, L. A. H.. An assessment of two Doppler-based monitors to track cardiac output changes in anaesthetised patients undergoing major surgery[J]. ANAESTHESIA AND INTENSIVE CARE,2014,42(5):631-639.
Service
Recommend this item
Sava as my favorate item
Show this item's statistics
Export Endnote File
Google Scholar
Similar articles in Google Scholar
[Huang, L.]'s Articles
[Critchley, L. A. H.]'s Articles
CSDL cross search
Similar articles in CSDL Cross Search
[Huang, L.]‘s Articles
[Critchley, L. A. H.]‘s Articles
Related Copyright Policies
Null
Social Bookmarking
Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit

Items in IR are protected by copyright, with all rights reserved, unless otherwise indicated.

 

 

Valid XHTML 1.0!
Copyright © 2007-2018  北京大学医学部 - Feedback
Powered by CSpace