北京大学医学部机构知识库
Advanced  
IR@PKUHSC  > 北京大学第二临床医学院  > 肾内科  > 期刊论文
学科主题: 临床医学
题名:
Clinical outcomes for maintenance hemodialysis patients using a high-flux (FX60) dialyzer
作者: Li, Yuehong; Wang, Yujuan; Lv, Jiaxuan; Wang, Mei
关键词: Anemia ; FX60 dialyzer ; hemodialysis ; high-flux hemodialysis (HFHD) ; hypertension
刊名: RENAL FAILURE
发表日期: 2013
DOI: 10.3109/0886022X.2013.823872
卷: 35, 期:9, 页:1240-1245
收录类别: SCI
文章类型: Article
WOS标题词: Science & Technology
类目[WOS]: Urology & Nephrology
研究领域[WOS]: Urology & Nephrology
关键词[WOS]: QUALITY-OF-LIFE ; MEMBRANE-PERMEABILITY ; HEMODIAFILTRATION ; MORTALITY ; PHOSPHATE ; ANEMIA
英文摘要:

Aims: To investigate the clinical outcomes of maintenance hemodialysis (HD) patients using a high-flux (FX60) dialyzer. Method: Thirty patients undergoing dialysis for at least 2 years with a low-flux dialyzer were switched to the FX60 dialyzer for 3 years. Clinical and biochemical analysis was performed monthly for each patient. The parameters monitored included blood pressure, hemoglobin, albumin, intact parathyroid hormone (iPTH), calcium and phosphorus levels, the adequacy of dialysis (Kt/V), beta2-microglobulin (beta 2-MG) clearance rate, as well as antihypertensive and erythropoietin (EPO) medications. Results: After 3 years of dialysis with an FX60 dialyzer, the mean arterial blood pressure fell, hemoglobin increased, serum phosphate level decreased, iPTH declined and medication doses decreased. Conclusions: Dialysis with the FX60 dialyzer has a better clinical outcome for rectifying renal anemia, controlling hypertension and lowering serum phosphate levels making it a better choice for long-term HD patients.

语种: 英语
WOS记录号: WOS:000324403100009
Citation statistics:
内容类型: 期刊论文
URI标识: http://ir.bjmu.edu.cn/handle/400002259/61353
Appears in Collections:北京大学第二临床医学院_肾内科_期刊论文

Files in This Item:

There are no files associated with this item.


作者单位: Peking Univ, Peoples Hosp, Dept Nephrol, Beijing 100044, Peoples R China

Recommended Citation:
Li, Yuehong,Wang, Yujuan,Lv, Jiaxuan,et al. Clinical outcomes for maintenance hemodialysis patients using a high-flux (FX60) dialyzer[J]. RENAL FAILURE,2013,35(9):1240-1245.
Service
Recommend this item
Sava as my favorate item
Show this item's statistics
Export Endnote File
Google Scholar
Similar articles in Google Scholar
[Li, Yuehong]'s Articles
[Wang, Yujuan]'s Articles
[Lv, Jiaxuan]'s Articles
CSDL cross search
Similar articles in CSDL Cross Search
[Li, Yuehong]‘s Articles
[Wang, Yujuan]‘s Articles
[Lv, Jiaxuan]‘s Articles
Related Copyright Policies
Null
Social Bookmarking
Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit

Items in IR are protected by copyright, with all rights reserved, unless otherwise indicated.

 

 

Valid XHTML 1.0!
Copyright © 2007-2017  北京大学医学部 - Feedback
Powered by CSpace