IR@PKUHSC  > 北京大学第一临床医学院  > 放射治疗科
学科主题临床医学
Value of additional strain analysis with feature tracking in dobutamine stress cardiovascular magnetic resonance for detecting coronary artery disease
Schneeweis, Christopher1; Qiu, Jianxing2; Schnackenburg, Bernhard3; Berger, Alexander1; Kelle, Sebastian1; Fleck, Eckart1; Gebker, Rolf1
关键词Dobutamine stress cardiovascular magnetic resonance Coronary artery disease Feature tracking Circumferential strain Wall motion abnormality
刊名JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE
2014-10-01
DOI10.1186/s12968-014-0072-2
16
收录类别SCI
文章类型Article
WOS标题词Science & Technology
类目[WOS]Cardiac & Cardiovascular Systems ; Radiology, Nuclear Medicine & Medical Imaging
研究领域[WOS]Cardiovascular System & Cardiology ; Radiology, Nuclear Medicine & Medical Imaging
关键词[WOS]MYOCARDIAL FEATURE TRACKING ; WALL-MOTION ; ISCHEMIA
英文摘要

Background: Dobutamine stress cardiovascular magnetic resonance (DS-CMR) has been established for the detection of coronary artery disease (CAD). The novel technique feature tracking (FT) analyses left ventricular circumferential strain (Ecc) thus offering detailed information about myocardial deformation. The purpose of this study was to evaluate FT based Ecc for the detection of myocardial ischemia during DS-CMR.

Methods: A total of 25 patients (18 males; mean age 64 +/- 10 years) with suspected or known CAD underwent a standardized high-dose DS-CMR protocol at 1.5 T. For FT analysis cine short axis (SAX) views (apical, medial, basal) at rest and during maximum dobutamine stress were used. None of the patients had wall motion abnormalities (WMAs) or impaired left ventricular function at rest or scar tissue. For analysis of Ecc the three SAX planes were divided into 16 segments (n = 400 segments). During stress 15 patients (34 segments) developed WMAs as assessed by visual analysis. All patients underwent x-ray coronary angiography for clinical reasons which served as the reference standard. Patients without WMAs during DS-CMR and exclusion of stenotic CAD were defined as normal (10 patients, 160 segments). In patients with significant CAD segments that were supplied by a vessel of >70% narrowing were defined as stenotic (n = 64). The remaining segments in patients with significant CAD were considered as remote (n = 176).

Results: At rest no differences in Ecc were observed between normal, stenotic and remote segments. High-dose dobutamine stress revealed highly significant differences between Ecc of normal and stenotic segments (p < 0.001), as well as between remote and stenotic segments (p < 0.001). The same observation took place for the absolute change of Ecc (p < 0.001 and p = 0.01). ROC analysis of Ecc during maximum DS-CMR differentiated normal from stenotic segments with a sensitivity of 75% and specificity of 67% using a cutoff -33.2% with an area under the curve of 0.78. Additional analysis of intermediate-dose dobutamine also showed a significant difference between normal and stenotic segments (p = 0.001).

Conclusion: FT based analysis of Ecc during intermediate- and high-dose DS-CMR was feasible and differentiated between stenotic, remote and normal segments. Quantitative assessment of Ecc with FT may improve the diagnostic accuracy of DS-CMR for detection of ischemia.

语种英语
WOS记录号WOS:000344190000001
引用统计
被引频次:12[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.bjmu.edu.cn/handle/400002259/63168
专题北京大学第一临床医学院_放射治疗科
作者单位1.Philips Res Hamburg, Hamburg, Germany
2.German Heart Inst Berlin, Dept Internal Med Cardiol, D-13353 Berlin, Germany
3.Peking Univ, Hosp 1, Dept Radiol, Beijing 100871, Peoples R China
推荐引用方式
GB/T 7714
Schneeweis, Christopher,Qiu, Jianxing,Schnackenburg, Bernhard,et al. Value of additional strain analysis with feature tracking in dobutamine stress cardiovascular magnetic resonance for detecting coronary artery disease[J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE,2014,16.
APA Schneeweis, Christopher.,Qiu, Jianxing.,Schnackenburg, Bernhard.,Berger, Alexander.,Kelle, Sebastian.,...&Gebker, Rolf.(2014).Value of additional strain analysis with feature tracking in dobutamine stress cardiovascular magnetic resonance for detecting coronary artery disease.JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE,16.
MLA Schneeweis, Christopher,et al."Value of additional strain analysis with feature tracking in dobutamine stress cardiovascular magnetic resonance for detecting coronary artery disease".JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE 16(2014).
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Schneeweis, Christopher]的文章
[Qiu, Jianxing]的文章
[Schnackenburg, Bernhard]的文章
百度学术
百度学术中相似的文章
[Schneeweis, Christopher]的文章
[Qiu, Jianxing]的文章
[Schnackenburg, Bernhard]的文章
必应学术
必应学术中相似的文章
[Schneeweis, Christopher]的文章
[Qiu, Jianxing]的文章
[Schnackenburg, Bernhard]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。