英文摘要:

Background

There may be significant difference between measurement of end-tidal carbon dioxide partial pressure (PetCO(2)) and arterial carbon dioxide partial pressure (PaCO2) during one-lung ventilation with low tidal volume for thoracic surgeries. Transcutaneous carbon dioxide partial pressure (PtcCO(2)) monitoring can be used continuously to evaluate PaCO2 in a noninvasive fashion. In this study, we compared the accuracy between PetCO(2) and PtcCO(2) in predicting PaCO2 during prolonged one-lung ventilation with low tidal volume for thoracic surgeries.

Methods

Eighteen adult patients who underwent thoracic surgeries with one-lung ventilation longer than two hours were included in this study. Their PetCO(2), PtcCO(2), and PaCO2 values were collected at five time points before and during one-lung ventilation. Agreement among measures was evaluated by Bland-Altman analysis.

Results

Ninety sample sets were obtained. The bias and precision when PtcCO(2) and PaCO2 were compared were 4.1 +/- 6.5 mmHg during two-lung ventilation and 2.9 +/- 6.1 mmHg during one-lung ventilation. Those when PetCO(2) and PaCO2 were compared were -11.8 +/- 6.4 mmHg during two-lung ventilation and -11.8 +/- 4.9 mmHg during one-lung ventilation. The differences between PtcCO(2) and PaCO2 were significantly lower than those between PetCO(2) and PaCO2 at all five time-points (p < 0.05).

Conclusions

PtcCO(2) monitoring was more accurate for predicting PaCO2 levels during prolonged one-lung ventilation with low tidal volume for patients undergoing thoracic surgeries.

语种: 英语
WOS记录号: WOS:000363183100032
Citation statistics:
内容类型: 期刊论文
URI标识: http://ir.bjmu.edu.cn/handle/400002259/64288
Appears in Collections:北京大学第一临床医学院_期刊论文

Files in This Item:

There are no files associated with this item.


作者单位: Peking Univ, Hosp 1, Dept Anesthesiol & Crit Care Med, Beijing 100871, Peoples R China

Recommended Citation:
Zhang, Hong,Wang, Dong-Xin. Noninvasive Measurement of Carbon Dioxide during One-Lung Ventilation with Low Tidal Volume for Two Hours: End-Tidal versus Transcutaneous Techniques[J]. PLOS ONE,2015,10(10).
Service
Recommend this item
Sava as my favorate item
Show this item's statistics
Export Endnote File
Google Scholar
Similar articles in Google Scholar
[Zhang, Hong]'s Articles
[Wang, Dong-Xin]'s Articles
CSDL cross search
Similar articles in CSDL Cross Search
[Zhang, Hong]‘s Articles
[Wang, Dong-Xin]‘s Articles
Related Copyright Policies
Null
Social Bookmarking
Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit

Items in IR are protected by copyright, with all rights reserved, unless otherwise indicated.

 

 

Valid XHTML 1.0!
Copyright © 2007-2017  北京大学医学部 - Feedback
Powered by CSpace