英文摘要:

BACKGROUND AND AIMS: Detection rate, influence of recording site, and subject posture for impedance monitoring of pharyngeal reflux of gastric contents remain unknown. We evaluated the ability of the impedance sensor for detection of various volumes of intrapharyngeal infusate at two sites and in two subject positions.

METHODS: Nineteen healthy subjects were studied using concurrent videoendoscopic, manometric, impedance, and pH recording.

RESULTS: Detection rate of simulated pharyngeal reflux events ranged between 87% and 100% for 1-4 mL. Detection rate for 0.1-1 mL volumes in the upright position was significantly higher (78-85%) when the impedance sensor was located at the proximal margin of the upper esophageal sphincter (UES) compared to 2 cm proximally (38-68%) (P < 0.001). With the sensor at 2 cm above the UES, the average detection rate for all volumes in the upright position was significantly less (P < 0.001) compared to the supine position (48% vs 84%). There was substantial variability in the magnitude of impedance changes induced by different infusates.

CONCLUSIONS: Impedance sensors can detect as small a volume as 0.1 mL and combined with a pH sensor can detect acidic and nonacidic liquid and mist reflux events. Sensor placement at the proximal margin of the UES yields the highest detection rate irrespective of subject posture compared to placement 2 cm proximally. Depending on the volume of refluxate and location of the impedance sensor, a substantial minority of simulated reflux events can be missed.

语种: 英语
WOS记录号: WOS:000243376500007
Citation statistics:
内容类型: 期刊论文
URI标识: http://ir.bjmu.edu.cn/handle/400002259/64716
Appears in Collections:北京大学第一临床医学院_期刊论文

Files in This Item:

There are no files associated with this item.


作者单位: 1.Peking Univ, Hosp 1, Beijing 100871, Peoples R China
2.Gunma Univ, Sch Med, Gunma, Japan
3.Med Coll Wisconsin, Div Gastroenterol & Hepatol, MCW Dysphagia Inst, Milwaukee, WI 53226 USA

Recommended Citation:
Aslam, Muhammad,Bajaj, Shailesh,Easterling, Caryn,et al. Performance and optimal technique for pharyngeal impedance recording: A simulated pharyngeal reflux study[J]. AMERICAN JOURNAL OF GASTROENTEROLOGY,2007,102(1):33-39.
Service
Recommend this item
Sava as my favorate item
Show this item's statistics
Export Endnote File
Google Scholar
Similar articles in Google Scholar
[Aslam, Muhammad]'s Articles
[Bajaj, Shailesh]'s Articles
[Easterling, Caryn]'s Articles
CSDL cross search
Similar articles in CSDL Cross Search
[Aslam, Muhammad]‘s Articles
[Bajaj, Shailesh]‘s Articles
[Easterling, Caryn]‘s Articles
Related Copyright Policies
Null
Social Bookmarking
Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit
所有评论 (0)
暂无评论
 
评注功能仅针对注册用户开放,请您登录
您对该条目有什么异议,请填写以下表单,管理员会尽快联系您。
内 容:
Email:  *
单位:
验证码:   刷新
您在IR的使用过程中有什么好的想法或者建议可以反馈给我们。
标 题:
 *
内 容:
Email:  *
验证码:   刷新

Items in IR are protected by copyright, with all rights reserved, unless otherwise indicated.

 

 

Valid XHTML 1.0!
Copyright © 2007-2017  北京大学医学部 - Feedback
Powered by CSpace