Correlation between contrast sensitivity and the lens opacities classification system III in age-related nuclear and cortical cataracts
Cheng Yong1,3; Shi Xuan2; Cao Xiao-guang1,3; Li Xiao-xin1,3; Bao Yong-zhen1,3
关键词contrast sensitivity visual function age-related cataract lens opacities classification system III
刊名CHINESE MEDICAL JOURNAL
2013-04-20
DOI10.3760/cma.j.issn.0366-6999.20123274
126期:8页:1430-1435
收录类别SCI
文章类型Article
WOS标题词Science & Technology
类目[WOS]Medicine, General & Internal
研究领域[WOS]General & Internal Medicine
关键词[WOS]QUALITY-OF-LIFE ; VISUAL FUNCTION ; ACUITY ; MORPHOLOGY ; VISION ; LASER ; GLARE ; ASSOCIATION ; SURGERY
英文摘要

Background Contrast sensitivity (CS) testing can detect differences in functional vision and is highly correlated with visual performance. This study was designed to investigate the association between CS and the grading score using the lens opacities classification system (LOCS) III as well as the association between CS and visual acuity (VA) in nuclear or cortical age-related cataract (ARC) patients.

Methods A total of 270 eyes with ARC and 30 control eyes were divided into nuclear opacity (NO), nuclear color (NC), cortical cataract (C) based on LOCS III. The CS values measured at all spatial frequencies under photopic and glare conditions that resulted in contrast sensitivity function (CSF) were evaluated, and LogMAR VA was tested with the Early Treatment Diabetic Retinopathy Study (ETDRS) chart. The correlation between CSF and LOCS III grading scores, and between CSF and LogMAR VA were analyzed.

Results Compared to the controls, CSF of the nuclear or cortical ARC significantly declined. There are significant correlation between CSF and LogMAR VA, and between CSF and LOCS III grading scores. Compared to the VA, a stronger correlation existed between CSF and LOCS III grading score than that of LogMAR VA and LOCS Ill grading score. CS at some spatial frequencies is significantly influenced with LOCS III grading score.

Conclusions CSF significantly declined with the increasing ARC grading scores. Comparing to VA, CSF reflected the severity of cataract more comprehensively. CS at low spatial frequency is significantly influenced by ARC. Therefore, CS is more precise than VA in assessing the visual function of ARC patients.

语种英语
WOS记录号WOS:000319529000006
引用统计
被引频次:5[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.bjmu.edu.cn/handle/400002259/65924
专题北京大学第二临床医学院_眼科
作者单位1.Peking Univ, Peoples Hosp, Dept Ophthalmol, Beijing 100044, Peoples R China
2.Peking Univ, Peoples Hosp, People Eye Inst, Beijing 100044, Peoples R China
3.Minist Educ, Key Lab Vis Loss & Restorat, Beijing 100044, Peoples R China
推荐引用方式
GB/T 7714
Cheng Yong,Shi Xuan,Cao Xiao-guang,et al. Correlation between contrast sensitivity and the lens opacities classification system III in age-related nuclear and cortical cataracts[J]. CHINESE MEDICAL JOURNAL,2013,126(8):1430-1435.
APA Cheng Yong,Shi Xuan,Cao Xiao-guang,Li Xiao-xin,&Bao Yong-zhen.(2013).Correlation between contrast sensitivity and the lens opacities classification system III in age-related nuclear and cortical cataracts.CHINESE MEDICAL JOURNAL,126(8),1430-1435.
MLA Cheng Yong,et al."Correlation between contrast sensitivity and the lens opacities classification system III in age-related nuclear and cortical cataracts".CHINESE MEDICAL JOURNAL 126.8(2013):1430-1435.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Cheng Yong]的文章
[Shi Xuan]的文章
[Cao Xiao-guang]的文章
百度学术
百度学术中相似的文章
[Cheng Yong]的文章
[Shi Xuan]的文章
[Cao Xiao-guang]的文章
必应学术
必应学术中相似的文章
[Cheng Yong]的文章
[Shi Xuan]的文章
[Cao Xiao-guang]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。