Impact of uncontrolled blood pressure on diagnostic accuracy of coronary flow reserve for detecting significant coronary stenosis in hypertensive patients
作者: Li Wei-hong1,2; Xu Wei-xian1,2; Li Zhao-ping1,2; Li Cui-ping1,2; Wang Xin-yu1,2; He Li-yun1,2; Zhao Wei1,2; Feng Xin-heng1,2; Gao Wei1,2
关键词: coronary flow reserve ; hypertension ; uncontrolled blood pressure ; transthoracic Doppler echocardiography ; diagnostic accuracy
刊名: CHINESE MEDICAL JOURNAL
发表日期: 2013-03-05
DOI: 10.3760/cma.j.issn.0366-6999.20123043
卷: 126, 期:5, 页:839-844
收录类别: SCI
文章类型: Article
WOS标题词: Science & Technology
类目[WOS]: Medicine, General & Internal
研究领域[WOS]: General & Internal Medicine
关键词[WOS]: TRANSTHORACIC DOPPLER-ECHOCARDIOGRAPHY ; ARTERIAL-HYPERTENSION ; MICROVASCULAR DYSFUNCTION ; VELOCITY RESERVE ; HEART-DISEASE ; IMPROVEMENT ; MANAGEMENT ; ANGIOGRAPHY ; CARDIOLOGY
英文摘要:

Background Impaired coronary flow reserve (CFR) in patients with hypertension may be caused by epicardial coronary stenosis or microvascular dysfunction. Antihypertensive treatment has been shown to improve coronary microvascular dysfunction. The aim of this study was to evaluate the impact of uncontrolled blood pressure (BP) on diagnostic accuracy of CFR for detecting significant coronary stenosis.

Methods A total of 98 hypertensive patients scheduled for coronary angiography (CAG) due to chest pain were studied. Of them, 45 patients had uncontrolled BP (defined as the office BP >= 140/90 mmHg (1 mmHg=0.133 kPa) in general hypertensive patients, or >= 130/80 mmHg in hypertensive individuals with diabetes mellitus), and the remaining 53 patients had well-controlled BP. CFR was measured in the left anterior descending coronary artery (LAD) during adenosine triphosphate-induced hyperemia by non-invasive transthoracic Doppler echocardiography (TTDE) within 48 hours prior to CAG. Significant LAD stenosis was defined as >70% luminal narrowing. Diagnostic accuracy of CFR for detecting significant coronary stenosis was analyzed with a receiver operating characteristic analysis.

Results CFR was significantly lower in patients with uncontrolled BP than in those with well-controlled BP (2.1 +/- 0.6 vs. 2.6 +/- 0.9, P <0.01). Multivariate linear regression analysis of the study showed that the value of CFR was independently associated with the angiographically determined degree of LAD stenosis (beta= -0.445, P <0.0001) and the presence of uncontrolled BP (beta= -0.272, P=0.014). With a receiver operating characteristic analysis, CFR <2.2 was the optimal cut-off value for detecting LAD stenosis in all hypertensive patients (AUC 0.83, 95%CI 0.75-0.91) with a sensitivity of 75%, a specificity of 78%, and an accuracy of 77%. A significant reduction of diagnostic specificity was observed in patients with uncontrolled BP compared with those with well-controlled BP (67% vs. 93%, P=0.031).

Conclusions CFR measurement by TTDE is valuable in the diagnosis of significant coronary stenosis in hypertensive patients. However, the diagnostic specificity is reduced in patients with uncontrolled BP.

语种: 英语
WOS记录号: WOS:000319783500008
Citation statistics:
内容类型: 期刊论文
URI标识: http://ir.bjmu.edu.cn/handle/400002259/66295
Appears in Collections:北京大学第三临床医学院_期刊论文

Files in This Item:

There are no files associated with this item.


作者单位: 1.Minist Educ, Key Lab Mol Cardiovasc Sci, Beijing 100191, Peoples R China
2.Peking Univ, Hosp 3, Key Lab Cardiovasc Mol Biol & Regulatory Peptides, Dept Cardiol,Minist Hlth, Beijing 100191, Peoples R China

Recommended Citation:
Li Wei-hong,Xu Wei-xian,Li Zhao-ping,et al. Impact of uncontrolled blood pressure on diagnostic accuracy of coronary flow reserve for detecting significant coronary stenosis in hypertensive patients[J]. CHINESE MEDICAL JOURNAL,2013,126(5):839-844.
Service
Recommend this item
Sava as my favorate item
Show this item's statistics
Export Endnote File
Google Scholar
Similar articles in Google Scholar
[Li Wei-hong]'s Articles
[Xu Wei-xian]'s Articles
[Li Zhao-ping]'s Articles
CSDL cross search
Similar articles in CSDL Cross Search
[Li Wei-hong]‘s Articles
[Xu Wei-xian]‘s Articles
[Li Zhao-ping]‘s Articles
Related Copyright Policies
Null
Social Bookmarking
Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit
所有评论 (0)
暂无评论
 
评注功能仅针对注册用户开放,请您登录
您对该条目有什么异议,请填写以下表单,管理员会尽快联系您。
内 容:
Email:  *
单位:
验证码:   刷新
您在IR的使用过程中有什么好的想法或者建议可以反馈给我们。
标 题:
 *
内 容:
Email:  *
验证码:   刷新

Items in IR are protected by copyright, with all rights reserved, unless otherwise indicated.

 

 

Valid XHTML 1.0!
Copyright © 2007-2017  北京大学医学部 - Feedback
Powered by CSpace