北京大学医学部机构知识库
Advanced  
IR@PKUHSC  > 北京大学第三临床医学院  > 骨科  > 期刊论文
学科主题: 临床医学
题名:
Cannulated Screw and Cable are Superior to Modified Tension Band in the Treatment of Transverse Patella Fractures
作者: Tian, Yun; Zhou, Fang; Ji, Hongquan; Zhang, Zhishan; Guo, Yan
刊名: CLINICAL ORTHOPAEDICS AND RELATED RESEARCH
发表日期: 2011-12-01
DOI: 10.1007/s11999-011-1913-z
卷: 469, 期:12, 页:3429-3435
收录类别: SCI
文章类型: Article
WOS标题词: Science & Technology
类目[WOS]: Orthopedics ; Surgery
研究领域[WOS]: Orthopedics ; Surgery
关键词[WOS]: FIXATION ; WIRE
英文摘要:

Although the modified tension band technique (eg, tension band supplemented by longitudinal Kirschner wires) has long been the mainstay for fixation of transverse fractures of the patella, it has shortcomings, such as bad reduction, loosening of implants, and skin irritation.

We conducted a retrospective comparison of the modified tension band technique and the titanium cable-cannulated screw tension band technique.

We retrospectively reviewed 101 patients aged 22 to 85 years (mean, 56.6 years) with AO/OTA 34-C1 fractures (n = 68) and 34-C2 fractures (n = 33). Fifty-two patients were in the modified tension band group and 49 were in the titanium cable-cannulated screw tension band group. Followup was at least 1 year (range, 1-3 years). Comparison criteria were fracture reduction, fracture healing time, and the Iowa score for knee function.

The titanium cable-cannulated screw tension band group showed improved fracture reduction, reduced healing time, and better Iowa score, compared with the modified tension band group. In the modified tension band group, eight patients experienced wire migration, three of these requiring a second operation. There were no complications in the titanium cable-cannulated screw tension band group.

The titanium cable-cannulated screw tension band technique showed superior results and should be considered as an alternative method for treatment of transverse patellar fractures.

Level III, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

语种: 英语
项目资助者: Department of Orthopaedics, Third Hospital of Peking University
WOS记录号: WOS:000296733400023
Citation statistics:
内容类型: 期刊论文
URI标识: http://ir.bjmu.edu.cn/handle/400002259/66845
Appears in Collections:北京大学第三临床医学院_骨科_期刊论文

Files in This Item:

There are no files associated with this item.


作者单位: Peking Univ, Hosp 3, Dept Orthopaed, Beijing 100191, Peoples R China

Recommended Citation:
Tian, Yun,Zhou, Fang,Ji, Hongquan,et al. Cannulated Screw and Cable are Superior to Modified Tension Band in the Treatment of Transverse Patella Fractures[J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH,2011,469(12):3429-3435.
Service
Recommend this item
Sava as my favorate item
Show this item's statistics
Export Endnote File
Google Scholar
Similar articles in Google Scholar
[Tian, Yun]'s Articles
[Zhou, Fang]'s Articles
[Ji, Hongquan]'s Articles
CSDL cross search
Similar articles in CSDL Cross Search
[Tian, Yun]‘s Articles
[Zhou, Fang]‘s Articles
[Ji, Hongquan]‘s Articles
Related Copyright Policies
Null
Social Bookmarking
Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit
所有评论 (0)
暂无评论
 
评注功能仅针对注册用户开放,请您登录
您对该条目有什么异议,请填写以下表单,管理员会尽快联系您。
内 容:
Email:  *
单位:
验证码:   刷新
您在IR的使用过程中有什么好的想法或者建议可以反馈给我们。
标 题:
 *
内 容:
Email:  *
验证码:   刷新

Items in IR are protected by copyright, with all rights reserved, unless otherwise indicated.

 

 

Valid XHTML 1.0!
Copyright © 2007-2017  北京大学医学部 - Feedback
Powered by CSpace