IR@PKUHSC  > 北京大学第三临床医学院  > 眼科
学科主题临床医学
Anterior Segment Optical Coherence Tomography Measurement of Flap Thickness After Myopic LASIK Using the Mona One Use-Plus Microkeratome
Chen, Hui-Jin; Xia, Ying-Jie; Zhong, Yan-Ying; Song, Xiao-Li; Chen, Yue-Guo
刊名JOURNAL OF REFRACTIVE SURGERY
2010-06-01
DOI10.3928/1081597X-20090710-04
26期:6页:403-410
收录类别SCI
文章类型Article
WOS标题词Science & Technology
类目[WOS]Ophthalmology ; Surgery
研究领域[WOS]Ophthalmology ; Surgery
关键词[WOS]IN-SITU KERATOMILEUSIS ; INTRALASE FEMTOSECOND LASER ; SUB-BOWMAN KERATOMILEUSIS ; SINGLE-USE HEAD ; CORNEAL FLAP ; REFRACTIVE SURGERY ; MECHANICAL MICROKERATOME ; EYES ; M2 ; REPRODUCIBILITY
英文摘要

PURPOSE: To analyze the accuracy and consistency of corneal flap thickness created in myopic LASIK using the Mona One Use-Plus microkeratome compared with the Mona M2 Single Use 90-mu m microkeratome.

METHODS: Bilateral LASIK was performed in 68 myopic patients. Flaps were created using the One Use-Plus microkeratome in 82 eyes (41 patients) and the M2 90-mu m microkeratome in 54 eyes (27 patients). Flap complications and visual outcomes were evaluated. Horizontal "High Res. Corneal" scan pattern of anterior segment optical coherence tomography (AS-OCT) was applied to measure flap thickness at five locations (0, +/- 2, and +/- 3.5 mm from the corneal vertex) on the first postoperative day.

RESULTS: No significant differences were noted in flap complications and visual outcomes between groups. The central flap thickness was dramatically thinner in the One Use-Plus group (114.7 +/- 10.1 mu m and 109.4 +/- 11.0 mu m for right and left eyes, respectively) than in the M2 group (155.6 +/- 14.8 mu m and 151.6 +/- 12.5 mu m for right and left eyes, respectively) (P<.001) The One Use-Plus did not show a markedly better uniformity than the M2; the variation was mainly observed in the periphery. Multiple linear regression showed that for the One Use-Plus, the steeper the preoperative keratometry, the thicker the flap thickness, and for the M2, the thicker the preoperative pachymetry, the thicker the flap (P<.1).

CONCLUSIONS: The One Use-Plus and M2 microkeratomes have similar safety and efficacy. The flap created by the One Use-Plus was much thinner than the flap created with the M2; however, the One Use-Plus can not realize a fully planar-shaped flap. [J Refract Surg. 2010;26(6):403-410.] doi:10.3928/1081597X-20090710-04

语种英语
WOS记录号WOS:000278702800005
引用统计
被引频次:7[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.bjmu.edu.cn/handle/400002259/67257
专题北京大学第三临床医学院_眼科
作者单位Peking Univ, Hosp 3, Ctr Eye, Beijing 100871, Peoples R China
推荐引用方式
GB/T 7714
Chen, Hui-Jin,Xia, Ying-Jie,Zhong, Yan-Ying,et al. Anterior Segment Optical Coherence Tomography Measurement of Flap Thickness After Myopic LASIK Using the Mona One Use-Plus Microkeratome[J]. JOURNAL OF REFRACTIVE SURGERY,2010,26(6):403-410.
APA Chen, Hui-Jin,Xia, Ying-Jie,Zhong, Yan-Ying,Song, Xiao-Li,&Chen, Yue-Guo.(2010).Anterior Segment Optical Coherence Tomography Measurement of Flap Thickness After Myopic LASIK Using the Mona One Use-Plus Microkeratome.JOURNAL OF REFRACTIVE SURGERY,26(6),403-410.
MLA Chen, Hui-Jin,et al."Anterior Segment Optical Coherence Tomography Measurement of Flap Thickness After Myopic LASIK Using the Mona One Use-Plus Microkeratome".JOURNAL OF REFRACTIVE SURGERY 26.6(2010):403-410.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Chen, Hui-Jin]的文章
[Xia, Ying-Jie]的文章
[Zhong, Yan-Ying]的文章
百度学术
百度学术中相似的文章
[Chen, Hui-Jin]的文章
[Xia, Ying-Jie]的文章
[Zhong, Yan-Ying]的文章
必应学术
必应学术中相似的文章
[Chen, Hui-Jin]的文章
[Xia, Ying-Jie]的文章
[Zhong, Yan-Ying]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。