英文摘要

Background: Bioimpedance (BI) is maturing as a clinical technique for assessing fluid volume status. The aim of this study was to compare the sensitivity of four BI methods to detect changes in fluid status in hemodialysis patients. Methods: Forty-five patients were studied twice in the same week, i.e. once after the long and short interdialytic intervals, respectively. The four BI methods used were: (a) calf normalized resistivity (CNR) at a 5-kHz frequency, (b) whole-body multifrequency BI spectroscopy (MF-BIS) to estimate the normal hydration weight (NHWWBM), (c) whole-body MF-BIS to estimate the ratio of extracellular volume to total body water (wECV/wTBW), and (d) whole-body single-frequency (50 kHz) BI analysis to compute the ratio of ECV (sfECV) to TBW (sfTBW). Results: The relationship (slope of the regressive line) between relative changes (%) in the above mentioned four BI parameters and differences in weight (kg) was most pronounced with CNR (5.2 +/- 1.6%/kg), followed by wECV/wTBW (1.7 +/- 0.7%/kg) and NHW WBM (0.73 +/- 0.2%/kg). Changes in sfECV/sfTBW and differences in weight were not correlated. Conclusions: CNR is more sensitive than whole-body BIS for detecting differences in fluid status. (C) 2014 S. Karger AG, Basel

语种英语
WOS记录号WOS:000333120400010
引用统计
被引频次:10[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.bjmu.edu.cn/handle/400002259/67456
专题北京大学第一临床医学院_肾脏内科
作者单位1.Renal Res Inst, New York, NY 10065 USA
2.Kaysei Univ Hosp, Kayseri, Turkey
3.Peking Univ, Div Renal, Dept Med, Hosp 1, Beijing 100871, Peoples R China
推荐引用方式
GB/T 7714
Abbas, Samer R.,Liu, Li,Sipahioglu, Murat H.,et al. Comparison of Bioimpedance Techniques to Detect Changes in Fluid Status in Hemodialysis Patients[J]. BLOOD PURIFICATION,2014,37(1):48-56.
APA Abbas, Samer R..,Liu, Li.,Sipahioglu, Murat H..,Rosales, Laura.,Carter, Mary.,...&Zhu, Fansan.(2014).Comparison of Bioimpedance Techniques to Detect Changes in Fluid Status in Hemodialysis Patients.BLOOD PURIFICATION,37(1),48-56.
MLA Abbas, Samer R.,et al."Comparison of Bioimpedance Techniques to Detect Changes in Fluid Status in Hemodialysis Patients".BLOOD PURIFICATION 37.1(2014):48-56.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Abbas, Samer R.]的文章
[Liu, Li]的文章
[Sipahioglu, Murat H.]的文章
百度学术
百度学术中相似的文章
[Abbas, Samer R.]的文章
[Liu, Li]的文章
[Sipahioglu, Murat H.]的文章
必应学术
必应学术中相似的文章
[Abbas, Samer R.]的文章
[Liu, Li]的文章
[Sipahioglu, Murat H.]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。