Evaluation of BD Vacutainer SST (TM) II Plus Tubes for Common Tumor Marker Tests by Roche Diagnostics Modular E 170 Analyzer
作者: Li, Zhiyan; Feng, Zhenru; Yan, Cunling; Yan, Rong
关键词: BD SST (TM) II Plus tubes ; serum separator tube ; stability ; barrier gel ; tumor marker
刊名: JOURNAL OF CLINICAL LABORATORY ANALYSIS
发表日期: 2010
DOI: 10.1002/jcla.20422
卷: 24, 期:6, 页:418-421
收录类别: SCI
文章类型: Article
WOS标题词: Science & Technology
类目[WOS]: Medical Laboratory Technology
研究领域[WOS]: Medical Laboratory Technology
关键词[WOS]: BLOOD-COLLECTION TUBES ; THERAPEUTIC DRUGS ; SERUM ; TIME ; ABSORPTION ; SPECIMENS ; VOLUME ; GEL
英文摘要:

Serum separator tubes were introduced 35 years ago and were widely used in the clinical laboratory in China for routine collection of blood because of providing a closed system that allowed for collection, transport, processing, sampling, and storage of specimens. This type of tubes facilitated rapid separation of serum from cellular constituents of blood and also prevented hemolysis upon prolonged storage. However, there were some limitations associated with gel tubes (i.e., gel and analyte stability). In order to circumvent these problems, BD released a new serum separator tube containing a new gel (BD SST (TM) II Plus). We investigated the performance of BD SST (TM) II Plus tubes for tumor marker tests using BD Serum Glass tubes as controls. Equivalence between the BD SST (TM) II Plus and BD Serum Glass tubes was demonstrated for all analytes at initial time. Also, all analytes remained stable when stored in BD SST (TM) II Plus tubes up to 72 hr. Concentration of neuron-specific enolase tended to increase with preservation time up to 72 hr in BD Serum Glass tubes. We conclude that BD SST (TM) II Plus was suitable for collection of blood and storage of serum for tumor marker tests. J. Clin. Lab. Anal. 24:418-421, 2010. (C) 2010 Wiley-Liss, Inc.

语种: 英语
WOS记录号: WOS:000284914700010
Citation statistics:
内容类型: 期刊论文
URI标识: http://ir.bjmu.edu.cn/handle/400002259/68007
Appears in Collections:北京大学第一临床医学院_期刊论文

Files in This Item:

There are no files associated with this item.


作者单位: Peking Univ, Hosp 1, Dept Clin Lab, Beijing 100871, Peoples R China

Recommended Citation:
Li, Zhiyan,Feng, Zhenru,Yan, Cunling,et al. Evaluation of BD Vacutainer SST (TM) II Plus Tubes for Common Tumor Marker Tests by Roche Diagnostics Modular E 170 Analyzer[J]. JOURNAL OF CLINICAL LABORATORY ANALYSIS,2010,24(6):418-421.
Service
Recommend this item
Sava as my favorate item
Show this item's statistics
Export Endnote File
Google Scholar
Similar articles in Google Scholar
[Li, Zhiyan]'s Articles
[Feng, Zhenru]'s Articles
[Yan, Cunling]'s Articles
CSDL cross search
Similar articles in CSDL Cross Search
[Li, Zhiyan]‘s Articles
[Feng, Zhenru]‘s Articles
[Yan, Cunling]‘s Articles
Related Copyright Policies
Null
Social Bookmarking
Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit
所有评论 (0)
暂无评论
 
评注功能仅针对注册用户开放,请您登录
您对该条目有什么异议,请填写以下表单,管理员会尽快联系您。
内 容:
Email:  *
单位:
验证码:   刷新
您在IR的使用过程中有什么好的想法或者建议可以反馈给我们。
标 题:
 *
内 容:
Email:  *
验证码:   刷新

Items in IR are protected by copyright, with all rights reserved, unless otherwise indicated.

 

 

Valid XHTML 1.0!
Copyright © 2007-2017  北京大学医学部 - Feedback
Powered by CSpace